AB Repair, New s7n ghd program

Our new Gold & Max S7N IC code for pcb repairs. Only available to SIRIUSHAIR LTD. If you have a faulty Gold & Max PCB you can send it to them for repair or replacment. 

Error codes.

If there is a fault with the PCB our new code will detect and display it by flashing the red LEDs in a sequence showing below.

  1. flash = Could not calculate the mains frequency or out of range (45 to 65hz).
  2. flash = Could not measure mains voltage or out of range (90 to 260v).
  3. flash = Switch side (button side) heater is not detected. (Check heater connections)
  4. flash = Non switch side heater is not detected. (Check heater connections)
  5. flash = Temperature has gone too high on the switch side heater while operating.
  6. flash = Heater on switch side failed to heat or lost heat (Check heater connections or replace heater)
  7. flash = Temperature has gone to high on the non side heater while operating.
  8. flash = Heater on non switch side failed to heat or lost heat (Check heater connections or replace heater)

Calibration

Because different heaters have a slightly different reading sometimes they may need adjusted in software. The software is only available to Siriushair.